Air purification to cut contamination and failures

Dust and corrosive gases are an invisible cause of server, switch and power-supply failures. QUATRO purifiers clean the air inside your critical rooms, and coupon testing proves the improvement.

The hidden cause of equipment failures

Servers pull room air through their components all day. Fine dust settles on heat sinks and fans, and in humid air it becomes slightly conductive. Gases such as sulphur dioxide, hydrogen sulphide and chlorine, common in coastal and industrial cities, react with the copper and silver on circuit boards. The result is overheating, intermittent faults, corrosion creep and short circuits.

  • Failed fans and power supplies
  • Black or green deposits on copper
  • Unexplained board and port failures
  • Equipment warranties that assume clean (G1) air

Advantages of air purification

Removes dust and particles

HEPA filtration at 99.97% for 0.3 µm particles keeps fans, heat sinks and filters clean.

Stops corrosive gases

Deep carbon beds adsorb sulphur and chlorine compounds before they reach circuit boards.

Fewer failures

Less contamination means fewer intermittent faults, short circuits and hardware replacements.

Better cooling efficiency

Clean heat sinks and coils transfer heat better, so equipment runs cooler.

Protects warranties

Keeps rooms in the mild class that IT manufacturers expect.

Proven by testing

Coupon testing before and after shows the measured improvement.

Test first, then purify

We place copper and silver reactivity coupons in your room for 30 days and grade it G1 to GX to ISA-71.04. We then size QUATRO purifiers to the result and re-test after installation to prove the room has reached the target class.

About air-quality testing View QUATRO purifiers
QUATRO reactivity monitoring coupon
FAQ

Common questions

Can't find your answer? Call or e-mail our engineers.

What causes contamination-related failures?

Fine dust clogs fans and heat sinks and, when humid, becomes conductive. Sulphur and chlorine gases from traffic, industry and the sea corrode copper and silver on circuit boards, causing intermittent faults and short circuits.

How quickly does purification help?

Particle levels fall within hours of start-up. Corrosion rates are verified with a 30-day coupon test after installation.

Book an air-quality test

Find out what is in your data center air before it causes failures.