Raised access flooring for data centers and offices

A raised floor carries your racks, hides power and data cabling, and delivers cold air exactly where it is needed. We have supplied and installed German-engineered MERO systems since 2004, alongside cost-effective Concorde panels and anti-static vinyl.

Why a raised floor

Flexible, serviceable and built for airflow

Every panel lifts out, so cabling, power and cooling can be changed without breaking a single tile. In a data center the floor void becomes the supply plenum, and perforated tiles place cold air exactly in front of the racks.

We have partnered with MERO-TSK International since 2004 and have installed raised floors in data centers, telecom switching centers and power plant control rooms across Pakistan.

  • MERO Type 2, Type 5, Type 6 and Type 3 steel systems
  • Perforated airflow panels and ESD vinyl
  • Load calculation for racks, UPS and rolling loads
  • Supply, installation, levelling, earthing and tile layout
  • Tested to EN 12825 for load, fire and safety
MERO · Made in Germany

MERO access floor systems

MERO Type 2 control room access floorMERO · Heavy duty

MERO Type 2 control room access floor

A self-supporting substructure with stringers on 600 × 600, 600 × 1200 or 1200 × 1200 mm grids, carrying wood-based or calcium sulphate panels. Built for power supply rooms, data processing and control rooms with heavy point and line loads.

PanelWood-based or calcium sulphate
Grid600 × 600, 600 × 1200, 1200 × 1200 mm
Load (walking area)3,000 to 20,000 N, DIN EN 12825
Frame sectionsUp to 20,000 N point load, 40,000 N line load
Typical useData centers, UPS and power rooms, control rooms
MERO Type 5 wood-based access floorMERO · Wood-based

MERO Type 5 wood-based access floor

22 to 38 mm wood-based panels on steel pedestals in a 600 × 600 mm grid. A cost-effective, comfortable and quiet floor for offices and IT areas, with a wide range of top coverings.

PanelWood-based (chipboard), 22 to 38 mm
Grid600 × 600 mm
Load2,000 to 5,000 N, DIN EN 12825
Typical useOffices, IT areas, light technical rooms
MERO Type 6 calcium sulphate access floorMERO · Calcium sulphate

MERO Type 6 calcium sulphate access floor

16 to 40 mm calcium sulphate or gypsum fibre panels: non-combustible, dimensionally stable and acoustically excellent. The first choice for data centers and high-quality offices.

PanelCalcium sulphate / gypsum fibre, 16 to 40 mm
FireBuilding material class A1 (non-combustible)
Load2,000 to 6,000 N, DIN EN 12825
Grid600 × 600 mm
Typical useData centers, offices
MERO Type 3 steel access floor (Classic & Dynamic)MERO · Steel

MERO Type 3 steel access floor (Classic & Dynamic)

Powder-coated steel panels for clean rooms, ESD-sensitive areas and high loads. The Dynamic version uses nested profiles bolted to the pedestals for maximum stability under rolling loads.

PanelPowder-coated steel
Classic loadUp to 6,000 N, DIN EN 12825
Dynamic load5,000 to 25,000 N
ESDConductive with matching adhesives and coverings
Typical useClean rooms, ESD areas, heavy-load data halls
MERO raised floor substructureMERO · Airflow

MERO perforated steel ventilation panels

Perforated steel panels that deliver conditioned air from the floor void to the racks, with optional lamella dampers to control air volume per tile. Complemented by fire bulkheads (F90) and sound-insulation bulkheads.

Free area24% to 65%
AirflowUp to approx. 2,800 m³/h at 10 Pa
Load3,000 to 10,000 N, DIN EN 12825
OptionsLamella air-volume control
Concorde

Concorde raised floor panels

Concorde calcium sulphate raised floorConcorde

Concorde calcium sulphate raised floor

A homogeneous high-density calcium sulphate and mineral-fibre core bonded to a galvanised steel base, with PVC edge trims. Excellent strength, stability and fire performance.

CoreHigh-density calcium sulphate + mineral fibre
BaseGalvanised steel plate
Uniform load35 kN/m²
Fire resistanceF60 / REI60
StandardBS EN 12825: 5A2
Top finishesHPL, vinyl, ceramic, granite
Concorde cementitious-core raised floorConcorde

Concorde cementitious-core raised floor

30 mm panels with a cement-filled metal core in a steel housing with black PVC edges. High rolling-load capacity and stable where humidity and temperature fluctuate.

Thickness30 mm
CoreCementitious infill in steel shell
Top finishesHPL, vinyl, rubber, linoleum, carpet
StrengthHigh rolling-load capacity
Concorde wood-core raised floorConcorde

Concorde wood-core raised floor

38 mm high-density particle board encapsulated in steel, with good fire resistance, sound insulation and a comfortable walking feel.

Thickness38 mm
Size600 × 600 mm
Fire resistanceF60
Electrical resistance1×10⁶ to 1×10¹⁰ Ω
StandardDIN EN 12825
Top finishesHPL, vinyl, ceramic, granite
Concorde

Concorde perforated panel & ESD vinyl tiles

Perforated airflow panels for cold aisles, and 600 × 600 × 2 mm conductive and static-dissipative ESD vinyl tiles for server rooms, labs and electronics areas.

Perforated size600 × 600 mm
Open area / airflowUp to 50%
Perforated finishesBare, HPL, vinyl
ESD vinylStatic-dissipative tiles for sensitive equipment

Looking for floor coverings? See our vinyl and ESD flooring range.

How a MERO access floor is built

1

Pedestals

Height-adjustable steel supports on a 600 × 600 mm grid, bonded or fixed to the slab and set to the required finished floor height.

2

Head pads

Conductive plastic pads locate each panel, carry static charge to earth and decouple the panel to cut impact sound.

3

Stringers

Recommended from about 500 mm floor height for lateral stability, or to raise the load class. Type 2 uses a screwed C-profile grid.

4

Panels

Wood-based (22–38 mm), calcium sulphate (16–40 mm) or steel panels, each liftable and interchangeable.

5

Covering

Factory-applied HPL, vinyl, ESD vinyl, rubber, linoleum, carpet or stone, matched to the room's use.

Choosing the right load class

Raised floors are rated to DIN EN 12825 by the point load a panel carries safely. Size it for the heaviest thing that will stand or roll on the floor, including racks being moved into place, UPS and battery cabinets, and pallet trucks.

Typical choice: offices 2–3 kN, IT rooms and data halls 4–6 kN, UPS, battery and plant rooms 6–10 kN or more.

MERO systemPoint load (DIN EN 12825)
Type 5 wood-based2,000 – 5,000 N
Type 6 calcium sulphate2,000 – 6,000 N
Type 3 steel Classicup to 6,000 N
Type 3 steel Dynamic5,000 – 25,000 N
Type 2 control-room floor3,000 – 20,000 N (frame up to 40,000 N/m line load)

Performance you can specify

Fire safety

Type 6 calcium sulphate panels are non-combustible (class A1). F90 fire bulkheads of aerated concrete and mineral wool seal the floor void between fire zones, and arc-fault fixing resists overpressure up to 200 mbar in switchrooms.

Airflow

Perforated steel panels offer 24–65% free area and up to about 2,800 m³/h at 10 Pa. Lamella dampers trim each tile from roughly 200 to 2,200 m³/h to balance the cold aisle.

Acoustics

Decoupled supports reduce impact sound by up to 34 dB, and mineral-wool sound bulkheads stop noise travelling through the void between rooms.

ESD control

Conductive head pads and dissipative coverings carry static safely to earth, with defined resistance values to EN 1081 and IEC 61340.

Accessories

Custom ramps and steps, brush cable outlets (300 × 200 mm), enclosure frames, bridging, front cladding and perforated panels.

Sustainability

Environmental Product Declarations (EPDs) are published for Type 5 and Type 6, supporting green-building documentation.

Installation and care

We survey the slab, set out the grid from the room's datum, install and level pedestals, fit stringers where specified, lay panels and cut-outs, then earth the floor and hand over the as-built layout with load and resistance data.

  • Always lift panels with a proper suction lifter and lift no more than needed at once
  • Never remove a row of panels next to heavy racks without temporary support
  • Replace perforated tiles only with the same free area to keep airflow balanced
  • Keep cable cut-outs sealed with brush grommets to stop cold air leaking
  • Clean with manufacturer-approved products; waxes can spoil ESD performance
FAQ

Common questions

Can't find your answer? Call or e-mail our engineers.

What is a raised access floor?

A raised access floor is a system of removable panels supported on adjustable steel pedestals above the structural slab. The void underneath carries power, data cabling and, in data centers, conditioned air, and any panel can be lifted for access.

Which panel type should I choose for a data center?

Calcium sulphate and cementitious-core panels are the usual choice for data centers because of their high load capacity, fire resistance and stability under changing humidity. Perforated panels are placed in the cold aisle to deliver air to the racks. We size the system to your rack loads and rolling loads.

Which standard do your floors meet?

Our MERO and Concorde systems are tested to EN 12825 (DIN EN 12825 / BS EN 12825), the European standard for raised access floors.

When are stringers needed?

MERO recommends stringers from a floor height of about 500 mm for lateral stability, and they are also used to increase the load class. The Type 2 control-room floor uses a screwed C-profile grid as standard.

Can a raised floor stop fire and noise spreading under walls?

Yes. F90 fire bulkheads and mineral-wool sound bulkheads are installed in the floor void under partition walls to keep fire zones and rooms separated.

Need a raised floor quotation?

Share your floor area, finished floor height and rack loads, and we'll recommend the right system.