Environmental monitoring for server rooms and data centers

Overheating, a water leak or a failed AC unit can take a server room down in minutes. As VUTLAN's exclusive distributor in Pakistan since 2008, we have installed hundreds of monitoring devices and thousands of sensors that watch temperature, humidity, smoke, power and doors around the clock.

Server racks with network cabling in a data center
Exclusive VUTLAN distributor since 2008

See problems before they become outages

VUTLAN systems combine sensors, logic and alerts in one unit. Set thresholds, and the system warns your team or acts on its own, for example switching on a standby fan or rebooting a frozen device through a switched PDU. We have installed VUTLAN systems in data centers and server rooms across Pakistan.

  • Temperature and humidity
  • Smoke and fire
  • Water leaks
  • AC voltage and power failure
  • Door and rack access
  • UPS and generator status
  • Fuel and tank levels
  • Fans, alarms and outlets
Controllers

Monitoring units

VUTLAN VT335G monitoring unitMonitoring unit

VUTLAN VT335G monitoring unit

A compact, versatile controller for server rooms, network cabinets and telecom shelters: plug-and-play analog sensors, a long-distance CAN bus for sensor chains, dry contacts and relays, all managed from a built-in web interface.

Analog sensor ports4, plug and play
CAN bus1, up to 225 m and up to 31 devices
Dry contact inputs4
Relay outputs2 (12 V)
ElementsUp to 800
Network10/100/1000 Mb/s Ethernet
MountingDesktop, 19" panel or wall bracket
BackupVT7670 4G LTE modem slot
VUTLAN VT825G data center monitoring unitMonitoring unit

VUTLAN VT825G data center monitoring unit

A 1U rack-mount controller for data centers, with eight auto-sensing analog ports, 32 dry contact inputs and latching power relays to control doors, fans, UPS and alarms.

Analog sensor ports8 × RJ12, auto-sensing
Dry contact inputs32
CAN bus1, up to 24 devices per chain
Relay outputs2 × 240 V/10 A latching + 2 × 12 V
ElementsUp to 1,000 (130 physical sensors)
Network10/100/1000 Mb/s Ethernet
Form factor19" 1U, 440 × 44 × 90 mm, 1.6 kg
BackupVT7670 4G LTE modem slot
VUTLAN VT855G corporate data center unitMonitoring unit

VUTLAN VT855G corporate data center unit

The flagship controller for corporate and multi-room data centers, with two CAN buses and eight dry contact outputs on top of the VT825G feature set.

Analog sensor ports8 × RJ12, auto-sensing
Dry contact inputs / outputs32 / 8
CAN bus2, up to 24 devices per chain
Relay outputs2 × 240 V/10 A latching + 2 × 12 V
ElementsUp to 1,000 (150 physical sensors)
Network10/100/1000 Mb/s Ethernet
Form factor19" 1U, 440 × 44 × 90 mm, 1.6 kg
Power

Switched and metered PDUs

VUTLAN VT608t switched PDU, 8 outletsSwitched IP PDU

VUTLAN VT608t switched PDU, 8 outlets

Switch on, off or reboot eight outlets remotely while monitoring the rack environment and controlling fans, UPS and alarms.

Outlets8 bistable relays, 10 A / 230 V
Power input16 A, 230 VAC
Analog ports / CAN2 / 1
Network10/100/1000 Mb/s
Mounting19"
Expansion4G modem, SD, USB-C
VUTLAN VT604t switched PDU, 4 outletsSwitched IP PDU

VUTLAN VT604t switched PDU, 4 outlets

The four-outlet version for smaller racks and network cabinets, with the same monitoring and control features.

Outlets4 bistable relays, 10 A / 230 V
Analog ports / CAN2 / 1
Network1000 Mb/s
VUTLAN VT-PDU 4PS and 4MSPDU

VUTLAN VT-PDU 4PS and 4MS

Compact switched (4PS) and switched-and-metered (4MS) PDUs with per-outlet control for racks and cabinets.

Outlets4, switched by outlet
4MSAdds per-outlet metering

How a VUTLAN system works

One monitoring unit sized to your facility, extended over the CAN bus with exactly the sensors each room needs, all managed from one web interface and fed into your NOC or DCIM.

  1. Sensor detectsA threshold is crossed: temperature, leak, smoke, open door, voltage.
  2. Logic decidesCodeless logic schemes, timers and triggers decide what happens next.
  3. Alert is sentE-mail, SMS, phone call, Telegram or SNMP trap within seconds.
  4. Action is takenSwitch a fan, reboot an outlet, start a generator, sound a beacon.

Scales from one rack to a whole campus

  • Up to 150 sensors and 1,000 elements per controller
  • CAN bus chains of up to 32 sensors and extensions, up to 225 m
  • VT408 adds 8 analog ports per unit, up to 24 units in a chain
  • Wireless LoRaWAN sensors up to 1 km indoors, no cabling
  • Codeless logic schemes, timers and virtual sensors built in

Integrates with what you already run

  • SNMP v1/v2c/v3, Modbus TCP and RTU, HTTP API (XML/JSON), RabbitMQ
  • Works with Zabbix, PRTG, Nagios and DCIM platforms
  • UPS, CRAC, generators, ATS and energy meters via Modbus or dry contacts
  • OpenVPN, HTTPS, RADIUS and three-level user permissions
  • 4G LTE or 5G modem for SMS alerts and network backup

Wireless LoRaWAN sensors

No cables to pull: one LR800 covers up to 100 sensors across floors, ideal for existing buildings.

VUTLAN LR800LR800

LoRaWAN wireless monitoring unit

  • Gateway, network server and web UI in one
  • Up to 100 wireless sensors
  • Up to 1 km indoor range, private network
VUTLAN LR490LR490

Wireless temperature & humidity

  • ±0.5 °C, ±3% RH
  • Battery powered, years of life
  • Tamper (open cover) alert
VUTLAN LR530LR530

Wireless access & temperature

  • Door and cabinet opening
  • Temperature reading
VUTLAN LR590LR590

Wireless leak, temperature & humidity

  • Water-leak detection
  • Temperature and humidity
VUTLAN LR560LR560

Wireless smoke sensor

  • Early smoke warning without cabling
LR-CO

Wireless carbon monoxide sensor

  • CO detection for generator and plant rooms
VUTLAN LR690LR690

Outdoor dual sensor

  • Waterproof housing for outdoor sites
  • Dual measurement channels

Climate and air-quality sensors

VUTLAN VT490VT490

Humidity & temperature sensor

  • ±0.4 °C, ±3% RH
  • CAN, daisy-chain up to 32
  • Up to 225 m from the unit
VUTLAN VT450VT450

Pressure, humidity & temperature

  • Differential aisle pressure
  • Condensation / dew point insight
VUTLAN VT500VT500

Precision temperature sensor

  • ±0.15 °C at room temperature
  • Plug-and-play analog, up to 100 m
VUTLAN VT515VT515

Outdoor / cold-room temperature

  • For cold storage and outdoor cabinets
VUTLAN VT510VT510

Humidity sensor

  • 10 to 95% RH, ±3%
  • Analog, up to 50 m
VUTLAN VT550VT550

Airflow velocity meter

  • 0 to 3 m/s
  • Confirms CRAC and fan airflow
VUTLAN VT580VT580

Dust particle sensor

  • 0 to 1,000 µg/m³, laser scattering
  • Air-quality and filter-clogging alerts

Fire, water and security sensors

VUTLAN VT460VT460

Smoke, humidity & temperature

  • Photoelectric smoke, high sensitivity
  • Ceiling heights up to 6 m
  • CAN, chainable
VUTLAN VT591 + WLCVT591 + WLC

Water-leak sensor and cable

  • Rope cable under floors and around CRACs
  • Cable lengths 3 to 50 m
VUTLAN VT593VT593

Spot leak sensor

  • Detects water, acids, alkalis, alcohols
  • Corrosion-resistant capacitive probe
VUTLAN VT530 / KMS-30VT530 / KMS-30

Door & cabinet contacts

  • Reed switch, IP68
  • Up to 500 m from the unit
VT570

PIR motion sensor

  • 110° detection angle
  • Up to 12 m range
VUTLAN VT572VT572

Radar motion sensor

  • Motion detection in shelters and halls
VUTLAN VT540VT540

Vibration sensor

  • Glass-break and tamper detection

Power and energy sensors

VUTLAN VT520VT520

AC voltage monitor

  • 0 to 246 V AC, ±1%
  • Detects mains failure and fluctuations
VUTLAN VT410VT410

DC voltage monitor

  • 0-15 V or 0-75 V DC
  • Battery strings and −48 V rectifiers
VUTLAN VT405 + CTVT405 + CT

AC / DC current converter

  • Hall-effect transducers 5 to 50 A
  • Load and overload monitoring
VT416

Bidirectional DC current

  • Battery charge and discharge current
VT420

4-20 mA converter

  • Diesel tank level, pressure and flow meters
VT424

Millivoltmeter

  • 0 to 24 mV DC
  • Shunt and low-voltage measurement

Alarms, control and access

VUTLAN VT103 / VT105VT103 / VT105

Alarm beacons

  • Light and siren, up to 108 dB
  • Driven by the unit's 12 V relays
VUTLAN VT109VT109

Light tower

  • Red, yellow and green status lights
VUTLAN VT11VT11

Dry contact relay output

  • Switches up to 5 A at 250 V AC
  • Start fans, generators, sirens
VUTLAN VT12VT12

Relay module

  • Two 12 V DC outputs with inputs
  • Door locks and small loads
VT485r + 8CD

Access readers & keypads

  • MIFARE DESFire cards and PIN
  • OSDPv2, IP54–IP67, vandal-proof

Extensions, modems and software

VUTLAN VT408VT408

Analog sensor extension

  • +8 analog ports per unit
  • Up to 24 units in a chain, 225 m
VUTLAN VT485m / VT485dVT485m / VT485d

Modbus RTU extension

  • Up to 32 Modbus devices
  • Chains up to 1,000 m
  • Each register becomes a virtual sensor
VUTLAN VT7670 / VT8230VT7670 / VT8230

4G LTE / 5G modem

  • SMS alerts and SMS control
  • Ethernet backup if the LAN fails
VUTLAN CAN-12V-1ACAN-12V-1A

CAN power supply

  • Powers each extra group of 12 CAN devices
VUTLAN VT-ACCUVT-ACCU

Backup battery module

  • Keeps VT825/VT855 alive through power loss

Where VUTLAN is used

Typical systems we design and install, and the products behind them.

Data centers & server rooms

Temperature and humidity at every rack inlet, smoke, leak cable around CRACs, door contacts on racks and rooms, switched PDUs and UPS status, all on one dashboard.

VT825G / VT855G · VT490 · VT460 · WLC · VT530 · VT608G

Remote telecom & BTS sites

Mains, −48 V rectifiers, battery voltage, generator run/fault, fuel tank level and shelter access, with LTE out-of-band alerts and remote generator start.

VT335G · VT520 · VT410 · VT420 · VT7670 · VT11

Generator & fuel monitoring

Continuous diesel level from 4-20 mA or ultrasonic sensors, with volume calculated for horizontal or vertical tanks, plus run hours and fault alarms.

VT420 · VT485m · dry contacts · logic schemes

Banks, offices & commercial buildings

One unit covers server room, comms risers, UPS room and plant room floor by floor, with wireless sensors where cabling is impractical.

LR800 · LR490 · LR590 · VT335G

Cold storage, labs & pharma

Logged temperature and humidity with alarms for excursions, door-open alerts and audit-ready history.

VT515 · VT490 · VT530 · VT580

Archives, museums & libraries

Stable humidity, dust and leak protection for collections, with discreet wireless sensors.

LR490 · VT580 · VT593

FAQ

Common questions

Can't find your answer? Call or e-mail our engineers.

What can a VUTLAN system monitor?

Temperature, humidity, smoke, water leaks, AC voltage, door contacts, UPS and generator status, and fuel or tank levels, using a wide range of plug-in sensors. Outputs can switch fans, alarms or PDU outlets automatically.

How are alerts sent?

Through the unit's built-in web interface, e-mail, SNMP and SMS. An optional 4G LTE modem keeps alerts flowing if the wired network fails.

Can it monitor remote sites without IT staff?

Yes. VUTLAN units are designed for unattended telecom shelters, branch server rooms and generator sites, and can be managed centrally.