Data center power and electrical works
Power is the backbone of every data center. We design and build the complete power train, from the utility connection and standby generators through LV switchgear, UPS and batteries to the PDU in every rack, and test it as one system.
One power train, from grid to rack
Most data center outages start with power. That is why we design the electrical system as one chain, with every stage sized, protected and redundant to match your tier target, and then test it end to end under load before handover.
See it in our 3D data center- Utility & transformer: incoming supply sized for present and future load.
- Generators & ATS: automatic standby power during grid outages.
- LV switchgear: protected, selective distribution of utility and generator power.
- UPS & batteries: clean, uninterrupted power while generators start.
- Distribution: power cabinets, busway and cabling to each row.
- Rack PDUs: Concorde basic, metered or smart PDUs, or VUTLAN switched IP PDUs, at every rack.
Power and electrical services
Utility connection & transformers
Coordination of the incoming supply, transformers and HT/LT connections, sized for today's load and future growth.
Standby generators & ATS
Diesel generator sets with automatic transfer switches, synchronising panels and fuel monitoring.
LV switchgear & distribution boards
Main LV panels, sub-distribution boards and protection designed for selectivity and safe maintenance.
UPS systems & batteries
Online UPS in N+1 or 2N configurations with VRLA or lithium battery banks sized for the required autonomy.
Power distribution to the rack
Power distribution cabinets, busway, H07RF-N and armoured cabling, and cable trays to every rack.
Rack PDUs & power monitoring
Concorde basic, metered and smart (switched) PDUs, and VUTLAN switched IP PDUs with environmental monitoring.
Earthing & lightning protection
Clean-earth systems, equipotential bonding and lightning protection for sensitive IT equipment.
Testing & maintenance
Load-bank testing, integrated systems testing, thermography and preventive maintenance.
Common questions
Can't find your answer? Call or e-mail our engineers.
What is the difference between N+1 and 2N power?
N+1 adds one spare unit (for example one extra UPS module) beyond what the load needs, so a single failure does not interrupt power. 2N provides two fully independent power paths, A and B, each able to carry the whole load, so even a complete path can be lost or maintained without downtime. The right choice depends on your tier target and budget.
How do you size a UPS and its batteries?
We start from the present and future IT load, power factor and redundancy level, then size battery autonomy to cover the time needed for generators to start and stabilise, typically a few minutes, or longer where the site needs extra ride-through.
Can you upgrade power in a live data center?
Yes. We plan changes around maintenance windows, use temporary feeds or bypasses where needed, and switch over in controlled steps so the IT load stays protected.
Planning a power upgrade?
Share your load, redundancy target and site drawings and we'll design the power train.