Raised access and vinyl flooring solutions

The floor is the foundation of every critical room. We design and install raised access floors and ESD vinyl together, so the floor carries the load, delivers the air, hides the cabling and keeps static under control.

Data hall with racks standing on a raised access floor

Advantages of a properly specified floor

Efficient cooling

The raised floor void becomes the cold-air plenum; perforated tiles deliver air exactly at the rack intakes, cutting cooling energy.

Hidden, flexible cabling

Power and data run under the floor, clear of walkways, and can be changed without breaking walls or ceilings.

Instant access

Any panel lifts out for maintenance, moves and upgrades, so changes take minutes, not days.

Static protection

Conductive pads and ESD vinyl carry static charge to earth, protecting sensitive electronics and staff.

Load capacity

Panels rated to EN 12825 carry racks, UPS and battery cabinets safely, including rolling loads during installation.

Fire and sound control

Non-combustible panels, F90 fire bulkheads and acoustic decoupling keep rooms safe and quiet.

Clean, durable finish

Hard-wearing vinyl is easy to clean, low in dust and suited to clean rooms, labs and technical areas.

Long life

Quality systems stay level and serviceable for decades and can be reconfigured as the room changes.

Which floor where?

We match the floor system and covering to each room after a site survey.

RoomTypical solution
Data hall / server roomRaised floor, 4–6 kN, perforated tiles, dissipative covering
UPS and battery roomHeavy-duty raised floor or ESD vinyl on slab
Control / NOC roomMERO Type 2 raised floor, acoustic covering
Electrical / LV roomDissipative ESD vinyl on slab
Clean room / electronics labSteel or calcium sulphate floor with conductive vinyl
OfficesType 5 wood-based floor with carpet or vinyl
FAQ

Common questions

Can't find your answer? Call or e-mail our engineers.

Do I need a raised floor or just vinyl?

Data halls with underfloor cooling or heavy cabling usually need a raised access floor with a suitable covering. Electrical rooms, labs, UPS rooms and offices without underfloor services can often use ESD vinyl tiles laid directly on the slab. We recommend after a site survey.

Can raised floor and vinyl be installed together?

Yes. Vinyl, including ESD vinyl, is a common factory-applied covering on raised floor panels, and we also lay matching vinyl in adjoining rooms so the whole facility is earthed and finished consistently.

Planning a new floor?

Share the room layout, finished floor height and equipment loads for a recommendation and quotation.